德图 testo 112单通道NTC温度仪,带声音报警功能,带电池和出厂报告 操作说明 |
|
|
Instructionmanualen
testo112
NTC-/Pt100measuringinstrument
Contents
Generalnotes......................................................2
1.Safetyadvice........................................................3
2.Intendedpurpose................................................4
3.Productdescription..............................................5
3.1Displayandcontrolelements..........................................5
3.2Interfaces........................................................................6
3.3Voltagesupply................................................................6
4.Commissioning....................................................7
5.Operation............................................................8
5.1Connectingaprobe........................................................8
5.2Switchingtheinstrumenton/off....................................8
5.3Switchingthedisplaylighton/off..................................9
5.4Performingsettings........................................................9
6.Measuring..........................................................12
7.Careandmaintenance......................................14
8.Questionsandanswers......................................15
9.Technicaldata....................................................16
10.Accessories/spareparts....................................17
Generalnotes2
Generalnotes
Thischapterprovidesimportantadviceonusingthis
documentation.
Thedocumentationcontainsinformationthatmustbe
appliediftheproductistobeusedsafelyandefficiently.
Pleasereadthisdocumentationthroughcarefullyand
familiariseyourselfwiththeoperationoftheproductbefore
puttingittouse.Keepthisdocumenttohandsothatyou
canrefertoitwhennecessary.
Identification
RepresentationMeaningComments
NoteOffershelpfultipsandinformation.
±,1,2ObjectiveDenotestheobjectivethatistobe
achievedviathestepsdescribed.Where
stepsarenumbered,youmustalways
followtheordergiven!
ConditionAconditionthatmustbemetifanaction
istobecarriedoutasdescribed.
i,1,2,...StepCarryoutsteps.Wherestepsare
numbered,youmustalwaysfollowthe
ordergiven!
TextDisplaytextTextappearsontheinstrumentdisplay.
ControlbuttonPressthebutton.
-ResultDenotestheresultofapreviousstep.
oCross-referenceReferstomoreextensiveordetailed
information.
Button
1.Safetyadvice3
1.Safetyadvice
Thischaptergivesgeneralruleswhichmustbefollowed
andobservediftheproductistobehandledsafely.
Avoidpersonalinjury/damagetoequipment
iDonotusethemeasuringinstrumentandprobesto
measureonornearliveparts.
iNeverstorethemeasuringinstrument/probestogether
withsolventsanddonotuseanydesiccants.
Productsafety/preservingwarrantyclaims
iOperatethemeasuringinstrumentonlywithinthe
parametersspecifiedintheTechnicaldata.
iAlwaysusethemeasuringinstrumentproperlyandforits
intendedpurpose.Donotuseforce.
iDonotexposehandlesandfeedlinestotemperaturesin
excessof70°Cunlesstheyareexpresslypermittedfor
highertemperatures.
Temperaturesgivenonprobes/sensorsrelateonlyto
themeasuringrangeofthesensors.
iOpentheinstrumentonlywhenthisisexpressly
describedinthedocumentationformaintenanceand
repairpurposes.
Carryoutonlythemaintenanceandrepairworkthatis
describedinthedocumentation.Followtheprescribed
stepswhendoingso.Forsafetyreasons,useonly
originalsparepartsfromTesto.
Ensurecorrectdisposal
iTakefaultyrechargeablebatteries/spentbatteriestothe
collectionpointsprovidedforthem.
iSendtheproductbacktoTestoattheendofitsuseful
life.Wewillensurethatitisdisposedofinan
environmentallyfriendlymanner.
de
en
fr
es
it
pt
sv
nl
??
??
2.Intendedpurpose4
2.Intendedpurpose
Thischaptergivestheareasofapplicationforwhichthe
productisintended.
Usetheproductonlyforthoseapplicationsforwhichitwas
designed.AskTestoifyouareinanydoubt.
testo112isacompact,accuratemeasuringinstrumentfor
measuringtemperaturesbymeansofplug-intemperature
probes.Thankstothepossibilityofconnectingnotonly
NTCprobes,butalsoPt100probes,thetesto112covers
awidemeasurementrangeandatthesametimeprovides
ahighlevelofmeasurementaccuracy.
Thefollowingcomponentsoftheproductaredesignedforcontinuous
contactwithfoodstuffsinaccordancewiththeregulation
(EC)1935/2004:
Themeasurementprobeupto1cmbeforetheprobehandleorthe
plastichousing.Ifprovided,theinformationaboutpenetrationdepths
intheinstructionmanualorthemark(s)onthemeasurementprobes
shouldbenoted.
Theproductwasdesignedforthefollowing
tasks/applications:
·Foodsector
·Laboratories
·Applicationsrequiringofficialcalibration(onlyrelevantfor
Germany):
Thetesto112isapprovedforofficialcalibrationbythe
Physikalisch-TechnischesInstitutPTB(national
metrologyinstituteinGermany).
Approvalmark:
Theproductshouldnotbeusedinthefollowingareas:
·Areasatriskofexplosion
·Diagnosticmeasurementsformedicalpurposes
3.Produktbeschreibung5
3.Productdescription
Thischapterprovidesanoverviewofthecomponentsof
theproductandtheirfunctions.
3.1Displayandcontrol
elements
Overview
?Infraredinterface,probesocket
?Display
?Controlbuttons
?Batterycompartment(rear)
Buttonfunctions
ButtonFunctions
Switchinstrumenton;
switchinstrumentoff(pressandhold)
Switchdisplaylighton/off
Keepreading,display
maximum/minimumvalue
Open/leaveconfigurationmode(press
andhold);
Inconfigurationmode:
Confirminput
Inconfigurationmode:
Increasevalue,selectoption
Inconfigurationmode:
Reducevalue,selectoption
Printdata
de
en
fr
es
it
pt
sv
nl
??
??
3.Productiondescription6
Importantdisplays
DisplayMeaning
Batterycapacity(bottomrightindisplay):
·4segmentsinthebatterysymbolarelit:Instrumentbatteryisfully
charged
·Nosegmentsinthebatterysymbolarelit:Batteryisalmostspent
Printfunction:Readingsaresenttotheprinter
Upperalarmlimit:Litifexceeded
Loweralarmlimit:Litifundershot
3.2Interfaces
Infraredinterface
MeasurementdatacanbesenttoaTestoprinterviathe
infraredinterfaceontheheadoftheinstrument.
Probesocket
Aplug-inmeasuringprobecanbeconnectedviatheprobe
socketontheheadoftheinstrument.
3.3Voltagesupply
Voltageissuppliedbymeansofa9Vmonoblocbattery
(includedindelivery)orrechargeablebattery.Itisnot
possibletoruntheinstrumentfromthemainssupplyor
chargearechargeablebatteryintheinstrument.
4.Commissioning7
4.Commissioning
Thischapterdescribesthestepsrequiredtocommission
theproduct.
2Removingtthepprotectiveffilmoonttheddisplay:
iPulltheprotectivefilmoffcarefully.
2Insertingaabbattery/rechargeablebbattery:
1Toopenthebatterycompartmentontherearofthe
instrument,pushthelidofthebatterycompartmentin
thedirectionofthearrowandremoveit.
2Insertabattery/rechargeablebattery(9Vmonobloc).
Observethepolarity!
3Toclosethebatterycompartment,replacethelidof
thebatterycompartmentinpositionandpushit
againstthedirectionofthearrow.
de
en
fr
es
it
pt
sv
nl
??
??
5.Operation8
5.Operation
Thischapterdescribesthestepsthathavetobeexecuted
frequentlywhenusingtheproduct.
5.1Connectingaprobe
Plug-inprobes
Plug-inprobesmustbeconnectedbeforethemeasuring
instrumentisswitchedonsothattheyarerecognisedby
theinstrument.
iInserttheconnectoroftheprobeintotheprobe
socket.
5.2Switchingtheinstrument
on/off
2Switchingttheiinstrumentoon:
iPress.
-Asegmenttestiscarriedout:AllLCD-segmentsin
thedisplaybrieflylightup.
-Afunctiontestoftheinstrumentandtheprobeis
carriedout.Theinstrumentteststheentire
measurementchannelregardingtheadherenceto
allowedmarginsoferror.
Thetypeofprobeattachedisdisplayedfor
approx.2s(NTCorPt100).
Anerrorisdetected:
-rEFErrorisdisplayedforapprox.2s,then-----is
displayed.PleasecontactyourdealerorTesto
customerservice.
Thefunctiontestwassuccessful:
-Measurementviewisopened:Thecurrentreading
isdisplayed.
5.Operation9
2Switchingttheiinstrumentooff:
iPressandhold(forapprox.2s)untilthedisplay
goesout.
5.3Switchingthedisplay
lighton/off
2Switchingttheddisplayllightoon/off:
Theinstrumentisswitchedon.
iPress.
5.4Performingsettings
1Tooopencconfigurationmmode:
Theinstrumentisswitchedonandisinmeasurement
view.Hold,MaxorMinarenotactivated.
iPressandhold(forapprox.2s)untilthedisplay
changes.
-Theinstrumentisnowinconfigurationmode.
Youcanchangetothenextfunctionwith.
Youcanleaveconfigurationmodeatanytime.Todo
so,pressandhold(forapprox.2s)untilthe
instrumenthaschangedtomeasurementview.Any
changesthathavealreadybeenmadeinconfiguration
modewillbesaved.
2Tossetttheaalarmffunction:
Configurationmodeisopened,ALARMislit.
1Selectthedesiredoptionwith/andconfirm
with:
·oFF:Switchesthealarmfunctionoff.
·on:Switchesthealarmfunctionon.
oFFwasselected:
oContinuewithobjectiveTOSETTHEMAX./MIN.PRINT
FUNCTION.
de
en
fr
es
it
pt
sv
nl
??
??
5.Operation10
onwasselected:
2Use/tosetthevaluefortheupperalarm
threshold()andconfirmwith.
3Use/tosetthevaluefortheloweralarm
threshold()andconfirmwith.
3Tossettthemmax./min.pprintffunction:
Configurationmodeisopened,MaxMinisflashing.
iSelectthedesiredoptionwith/andconfirm
with:
·on:Maximumandminimumvaluesareprintedout
aswellwhencurrentorrecordedreadingsare
printed.
·oFF:Maximumandminimumvaluesarenotprinted
outaswellwhencurrentorrecordedreadingsare
printed.
4TossetAAutoOOff:
Configurationmodeisopened,AutoOffisflashing.
iSelectthedesiredoptionwith/andconfirm
with:
·on:Themeasuringinstrumentswitchesoff
automaticallyifnobuttonispressedfor10min(Hold
orAutoHoldislit).
·oFF:Themeasuringinstrumentdoesnotswitch
itselfoffautomatically.
5Tossetttheddate/time:
Configurationmodeisopened,YEARislit.
1Use/tosetthecurrentYEARandconfirm
with.
2Use/tosettheothervaluesforthemonth
(MONTH),day(DAY)andtime(TIME)andconfirmeach
onewith.
5.Operation11
6Tossetttheuunitoofmmeasurement:
Configurationmodeisopened,UNITislit.
iSelectthedesiredunitofmeasurementwith/
andconfirmwith.
7Torreset:
Configurationmodeisopened,RESETislit.
iSelectthedesiredoptionwith/andconfirm
with:
·no:Instrumentisnotreset.
·Yes:Instrumentisreset.Theinstrumentisresetto
thefactorysettings.
Thesettingofdate/timeisnotreset.
-Theinstrumentreturnstomeasurementview.
de
en
fr
es
it
pt
sv
nl
??
??
6.Measuring12
6.Measuring
Thischapterdescribesthestepsthatarerequiredto
performmeasurementswiththeproduct.
2Takingaammeasurement:
Theinstrumentisswitchedonandisinmeasurement
view.
iPuttheprobeinpositionandreadoffthereadings.
Withthealarmfunctiononandifthealarmthreshold
isexceededorundershot:
-orflashesandasignaltoneisgiven.
-Thealarmgoesoutifthereadinggoesbelowthe
upperorabovethelowerthresholdagain.
2Holdingttherreading,ddisplayingtthemmaximum/minimum
value:
Thecurrentreadingcanberecorded.Themaximumand
minimumvalues(sincetheinstrumentwaslastswitched
on)canbedisplayed.
iPressseveraltimesuntilthedesiredvalueis
displayed.
-Thefollowingaredisplayedinturn:
·Hold:therecordedreading
·Max:Maximumvalue
·Min:Minimumvalue
·Thecurrentreading
-Inadditiontothemaximumorminimumreadings,
the2
nd
readinglineshowsthecurrentreading.
6.Measuring13
2Resettingtthemmaximum/minimumvvalues:
Themaximum/minimumvaluesofallchannelscanbe
resettothecurrentreading.
1PressseveraltimesuntilMaxorMinlightsup.
2Pressandhold(approx.2s).
-Allmaximumorminimumvaluesareresettothe
currentreading.
2Printingrreadings:
Thereadingsshownonthedisplay(currentreading,
recordedreadingormax./min.reading)canbeprinted
out.
ATestoprinterisrequired(accessorypart).
WiththeMax./Min.printfunctionswitchedon,the
maximumandminimumvaluesareprintedoutaswell
asthecurrentreadingorrecordedreading.
oSeethechapterPERFORMINGSETTINGS.
1Configuretheinstrumentsothatthevaluetobe
printedisshownonthedisplay.
2Press.
-Theprintoutstarts.Ontheprintoutappears:
·Themeasurementvalue
·Thedateandtime
Onlyrelevantforapplicationsrequiringofficial
calibrationinGermany:
·Aprotocollinewiththetext:
DerausgedruckteMesswertstimmtmitderAnzeige
desgeeichtenMessger?tsüberein.(Theprinted
measurementvaluecorrespondstothedisplay
oftheofficiallycalibratedmeasuringinstrument.)
·Asignatureline
de
en
fr
es
it
pt
sv
nl
??
??
7.Careandmaintenance14
7.Careandmaintenance
Thischapterdescribesthestepsthathelptomaintainthe
functionalityoftheproductandextenditsservicelife.
±Cleaningtthehhousing:
iCleanthehousingwithamoistcloth(soapsuds)ifit
isdirty.Donotuseaggressivecleaningagentsor
solvents!
±Changingtthebbattery/rechargeablebbattery:
Theinstrumentisswitchedoff.
1Toopenthebatterycompartmentontherearofthe
instrument,pushthelidofthebatterycompartmentin
thedirectionofthearrowandremoveit.
2Removethespentbattery/rechargeablebatteryand
insertanewbattery/rechargeablebattery
(9Vmonobloc).Observethepolarity!
3Toclosethebatterycompartment,replacethelidof
thebatterycompartmentinpositionandpushit
againstthedirectionofthearrow.
8.Questionsandanswers15
8.Questionsandanswers
Thischaptergivesanswerstofrequentlyaskedquestions.
QuestionPossiblecausesPossiblesolution
islit(bottomright·Instrumentbatteryis·Replaceinstrument
indisplay).almostspent.battery.
Instrumentswitches·AutoOfffunction·Switchfunctionoff.
itselfoffautomatically.isswitchedon.
·Residualcapacity·Replacebattery.
ofbatteryistoolow.
Display:-----·Probeisnotpluggedin.·Switchinstrumentoff,
connectprobeand
switchinstrument
backonagain.
·Probebreak.·Pleasecontactyour
dealerorTesto
CustomerService.
Displayreactsslowly·Ambienttemperature·Raiseambient
isverylow.temperature.
Display:uuuuu·Permittedmeasuring·Keeptopermitted
rangewasundershot.measuringrange.
Display:ooooo·Permittedmeasuring·Keeptopermitted
rangewasexceeded.measuringrange.
Display:rEFError·Referencemeasurement·Pleasecontactyour
outoftoleranceofdealerorTesto
±0.1°CCustomerService.
Ifweareunabletoansweryourquestion,pleasecontact
yourdealerorTestoCustomerService.Contactdetailscan
befoundontheguaranteecardorontheInternetunder
www.testo.com.
de
en
fr
es
it
pt
sv
nl
??
??
9.Technicaldata16
9.Technicaldata
Instrument
CharacteristicValue
ParametersTemperature(°C/°F)
MeasuringrangePt100probe:-50...+300°C/-58...+572°F
NTCprobe:-50...+120°C/-58...+248°F
Resolution0.1°C/0.1°F
AccuracyoSeeSYSTEMACCURACY
Probe1xminiDINsocketforPt100orNTCtemperatureprobe
Measuringrate2/s
Operatingtemperaturerange-20...+50°C/-4...+122°F
Storagetemperature-30...+70°C/-22...+158°F
Voltagesupply1x9Vmonoblocbattery/rech.battery
Batterylifeapprox.70h
ProtectionclasswithTopSafe(accessorypart)andprobeconnected:IP65
ECDirective89/336/EEC
Warranty2years
Systemaccuracy
MeasuringrangeInstrumentProbeSystem
Measuringinstrument+NTCtemperatureprobe
-50.0°C...-25.1°C±1%ofreading±0.7%ofreading±1.8%ofreading
-25.0...+40.0°C±0.2°C±0.2°C±0.5°C
+40.1...+80.00°C±0.3°C±0.4°C±0.8°C
+80.1...+120.0°C±0.5°C±0.6°C±1.2°C
Measuringinstrument+Pt100temperatureprobe
-50.0...-25.1°C±0.2°C±0.3°C±0,6°C
-25.0...+40.0°C±0.2°C±0.2°C±0.5°C
+40.1...+140.0°C±0.2°C±0.4°C±0.7°C
+140.1...+200.0°C±0.2°C±0.6°C±0.9°C
+200.1...+300.0°C±0.3°C±0.8°C±1.2°C
10.Accessories/spare
parts
NamePartno.
NTCprobes
Water-proofNTCimmersion/penetrationprobe06131212
Water-proofNTCsurfaceprobeforsmoothsurfaces06131912
Efficient,robustairprobe,NTC06131712
Pt100probes
Robust,water-proofPt100immersion/penetrationprobe06091273
Efficient,robustairprobe,Pt10006091773
Miscellaneous
TopSafetesto112,protectsfromimpactanddirtparticles05160221
Foracompletelistofallaccessoriesandspareparts,
pleaserefertotheproductcataloguesandbrochuresor
lookupourwebsite:www.testo.com
10.Accessories/spareparts17
de
en
fr
es
it
pt
sv
nl
??
??
|
|
|
|
|
|
|
|