分享

石子河市MedAccred _AC8102热处理基准审核标准【35】

 AS质量培训中心 2021-08-04

17.3.2 Thermal Treatment Step Two Age/PPT/Second Temper SECTION NA

17.3.2.1 Step Two Age/PPT/Second Temper

17.3.2.1.1 Furnace used:

17.3.2.1.2 Date part(s) processed:

17.3.2.2 Does the furnace possess the control and recording instrumentation required by the governing specification for this heat treatment? YES/NO

17.3.2.3 (EC) Step Two Age/PPT/Second Temper – Temperature



REQUIREMEN

T

SHOP PAPER

REQUIREMENT

SET

TEMPERATUR

E

ACTUAL

TEMPERATURES

Temperature


(EC)

(EC)

(EC)


Check if used






Control





(EC)

Recorder





(EC)

High/Low -

Type A or C

Instrumentation





(EC)

Load

Thermocouples





(EC)

17.3.3 (EC) Step Two Age/PPT/Second Temper – Time


REQUIREMENT

SHOP PAPER

REQUIREMENT

ACTUAL

Atmosphere

(EC)

(EC)

(EC)

Time and Tolerance

(EC)

(EC)

(EC)

Time loaded into

furnace




Time start of soak



(EC)

Time end of soak



(EC)

Media for Cooling

(EC)

(EC)

(EC)

Cooling Rate

(Excluding Quench)

(EC)

(EC)

(EC)